Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.178
Filtrar
1.
Anal Methods ; 16(15): 2368-2377, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38572530

RESUMO

Microfluidic technology has great advantages in the precise manipulation of micro-nano particles, and the hybrid microfluidic separation technology has attracted much attention due to the advantages of both active and passive separation technology at the same time. In this paper, the hydrophoresis sorting technique is combined with the dielectrophoresis technique, and a dielectrophoresis-assisted hydrophoresis microdevice is studied to separate blood cells. By using the dielectrophoresis force to change the suspension position of the cells in the channel, the scope of the hydrophoresis device for sorting particles is expanded. At the same time, the effects of microchannel width, fluid velocity, and electrode voltage on cell sorting were discussed, and the cell separation process was simulated. This work has laid a certain theoretical foundation for the rapid diagnosis of diseases in practical applications.


Assuntos
Técnicas Analíticas Microfluídicas , Técnicas Analíticas Microfluídicas/métodos , Simulação por Computador , Microfluídica , Eletroforese/métodos , Separação Celular/métodos
2.
Biosensors (Basel) ; 14(3)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38534226

RESUMO

Analyte migration order is a major aspect in all migration-based analytical separations methods. Presented here is the manipulation of the migration order of microparticles in an insulator-based electrokinetic separation. Three distinct particle mixtures were studied: a binary mixture of particles with similar electrical charge and different sizes, and two tertiary mixtures of particles of distinct sizes. Each one of the particle mixtures was separated twice, the first separation was performed under low voltage (linear electrokinetic regime) and the second separation was performed under high voltage (nonlinear electrokinetic regime). Linear electrophoresis, which discriminates particles by charge, is the dominant electrokinetic effect in the linear regime; while nonlinear electrophoresis, which discriminates particles by size and shape, is the dominant electrokinetic effect in the nonlinear regime. The separation results obtained with the three particle mixtures illustrated that particle elution order can be changed by switching from the linear electrokinetic regime to the nonlinear electrokinetic regime. Also, in all cases, better separation performances in terms of separation resolution (Rs) were obtained by employing the nonlinear electrokinetic regime allowing nonlinear electrophoresis to be the discriminatory electrokinetic mechanism. These findings could be applied to analyze complex samples containing bioparticles of interest within the micron size range. This is the first report where particle elution order is altered in an iEK system.


Assuntos
Eletricidade , Poliestirenos , Tamanho da Partícula , Eletroforese/métodos
3.
Methods Mol Biol ; 2763: 45-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347398

RESUMO

Studying salivary gland mucins is important for elucidating the pathogenesis of salivary gland diseases, including tumors and xerostomia, and developing diagnostic methods for them. Classic methods for isolating mucins from salivary glands require sacrificing several animals to obtain sufficient quantities of mucin and are time-consuming. Supported molecular matrix electrophoresis (SMME) was used to characterize mucins and their glycans. With this method, mucins can be analyzed within 2 days using less than 100 mg of tissue and without using expensive equipment, such as an ultracentrifuge. This chapter describes a method for preparing mucin solutions for SMME analysis of salivary gland mucins.


Assuntos
Mucinas , Glândula Submandibular , Animais , Glândula Submandibular/química , Glândulas Salivares , Eletroforese/métodos , Polissacarídeos
4.
Methods Mol Biol ; 2763: 79-97, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347402

RESUMO

Distinct bands of mucins cannot be banded using a gel electrophoresis based on a molecular sieving effect due to their very large molecular weight and remarkable diversity in glycosylation. In contrast, membrane electrophoresis can separate mucins as round bands. Here, we present an analysis of mucin separation via membrane electrophoresis using a porous polyvinylidene difluoride membrane, which is highly stable against chemical modifications and various organic solvents. The separated mucins can not only be stained with dyes but also with antibodies and lectins, and glycans can be released from the excised bands and analyzed.


Assuntos
Corantes , Mucinas , Eletroforese/métodos , Mucinas/química , Corantes/química , Lectinas , Glicosilação , Eletroforese em Gel de Poliacrilamida
5.
J Chromatogr A ; 1717: 464685, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38310700

RESUMO

This study contributes to the renewed interest in the study of nonlinear electrophoresis of colloidal particles. In this work the influence of cell shape on electrophoretic migration under the nonlinear regimes of moderate and strong field regimes was assessed. Four types of bacterial and yeast cells (one spherical, three non-spherical) were studied and their electrophoretic mobilities for the moderate and strong electric field magnitude regimes were estimated experimentally. The parameter of sphericity was employed to assess the effect cell shape on the nonlinear electrophoresis migration velocity and corresponding mobility under the two electric field magnitude regimes studied. As particle migration under nonlinear electrophoresis depends on particle size and shape, the results in terms of mobilities of nonlinear electrophoresis were presented as function of cell hydrodynamic diameter and sphericity. The results indicated that the magnitude of the mobilities of nonlinear electrophoresis for cells increase with increasing cell size and increase with increasing deviations from spherical shape, which is indicated by lower sphericity values. The results presented here are the very first assessment of the two types of mobilities of nonlinear electrophoresis of cells as a function of size and shape.


Assuntos
Eletricidade , Hidrodinâmica , Forma Celular , Eletroforese/métodos , Tamanho da Partícula
6.
Anal Chem ; 95(45): 16453-16458, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37916921

RESUMO

Synchronous coefficient of drag alteration refers to a multidimensional transport mechanism where a net drift of molecules is achieved under a zero-time-average alternating motive force by perturbing their drag coefficient synchronously with the applied force. An electrophoretic form of the method is often applied to focus and purify nucleic acids in a gel under rotating electric fields. However, this method requires lengthy operation due to the use of limited field strengths. Here, using DNA as target molecules, we demonstrate that the operation time can be reduced from hours to minutes by replacing polymer gel with a microfabricated artificial sieve. We also describe an electrophoretic protocol that facilitates the collection of purified DNA from the sieve, which is shown to yield amplifiable DNA from crude samples including the lysates of cultured cells and whole blood. The sieve can be further equipped with nucleic acid amplification and detection functions for a point-of-care diagnostic application.


Assuntos
DNA , Ácidos Nucleicos , Eletroforese/métodos , Polímeros , Técnicas de Amplificação de Ácido Nucleico
7.
Sci Rep ; 13(1): 17281, 2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828082

RESUMO

Dielectrophoresis (DEP) is widely utilized for trapping and sorting various types of cells, including live and dead cells and healthy and infected cells. This article focuses on the dielectric characterization of erythrocytes (red blood cells or RBCs) by quantifying DEP crossover frequency using a novel point-and-planar microwell device platform. Numerical simulations using COMSOL Multiphysics software demonstrate that the distribution of the DEP force is influenced by factors such as the shape of the point electrode, spacing between the point and planar electrodes, and the type of bioparticle being investigated. The dependency on electrode spacing is experimentally evaluated by analyzing the DEP crossover response of erythrocytes. Furthermore, the results are validated against the traditional electrical characterization technique called electrorotation, which typically requires laborious fabrication and operation using quadrupole electrodes. Other significant factors, including erythrocyte storage age and the changes in cell properties over time since collection, osmolarity, and temperature, are also assessed to determine the optimal conditions for erythrocyte characterization. The findings indicate a significant difference between fresh and stored erythrocyte samples (up to 4 days), highlighting the importance of maintaining an isotonic medium for cell storage.


Assuntos
Eritrócitos , Estresse Fisiológico , Temperatura , Eletroforese/métodos , Eletrodos
8.
Appl Microbiol Biotechnol ; 107(24): 7647-7655, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37815615

RESUMO

Immotile yeast cells were transiently moved in nonuniform sinusoidal electric fields using multiple pairs of micro-parallel cylindrical electrodes equipped with a sequential signal generator (SSG) to analyze cell viability at a clinical scale for the brewery/fermentation industry. Living yeast cells of Saccharomyces cerevisiae during the exponential-stationary phase, with a cell density of 1.15 × 105 cells mL-1 were suspended in sucrose medium. The conductivity (σs) was adjusted to 0.01 S m-1 with added KCl. Cells exposed in electric field strengths ranging from 32.89 to 40.98 kV m-1, exhibited positive dielectrophoresis (pDEP) with the lower critical frequencies (LCF) at 85.72 ± 3.59 kHz. The optimized value of LCF was shifted upwards to 780.00 ± 83.67 kHz when σswas increased to 0.10 S m-1. Dielectrophoretic and LCF spectra (translational speed of cells vs. electric field frequencies) of yeast suspensions during positive dielectrophoresis were analyzed in terms of the dielectric properties of the cell membrane and cytoplasm which reflect yeast cell viability and metabolic health status. The dielectrophoretic collection yield of cells using positive dielectrophoresis was reported on the monitor of sequential signal generator software to evaluate the number of living and dead cells through a real-time image processing analyzer. The spectra of both positive dielectrophoresis of the living and dead cells had distinguishable dielectric properties. The conductivity of the yeast cytoplasm (σc) of the dead cells was significantly less (≈ ≤ 0.05 S m-1) than that of the living yeast cells which typically had a cytoplasmic conductivity of ≈ 0.2 S m-1. This difference between viable and non-viable cells is sufficient for cell separation procedures. KEY POINTS: • Dielectrophoresis can be used to separate viable and non-viable yeast cells, • Cellular dielectric properties can be derived from the analysis of their dielectric spectra, • Cytoplasmic conductivity of viable cells is ≈ 0.2 S m-1 while that of non-viable cells ≈ ≤ 0.05 S m-1.


Assuntos
Eletricidade , Saccharomyces cerevisiae , Citoplasma , Condutividade Elétrica , Membrana Celular , Eletroforese/métodos
9.
Electrophoresis ; 44(23): 1837-1846, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37753817

RESUMO

Malaria is a tropical disease caused by parasites in the genus Plasmodium, which still presents 241 million cases and nearly 627,000 deaths recently. In this work, we used the dielectrophoresis (DEP) to characterize red blood cells in a microchannel. The purpose of this work is to determine the difference between the normal and the malaria-infected cells based on the DEP characteristics. The samples were infected cells and normal red blood cells, which were either prepared in culture or obtained from volunteers. Diamond-shaped and curved micropillars were used to create different degrees of DEP in the gap between them. The DEP crossover frequencies were observed with the diamond-shaped micropillars. The cell velocity under negative dielectrophoresis (nDEP) at a low frequency was examined with the curved micropillars. The measured lower crossover frequencies were remarkably different between the malaria-infected cells and the normal cells, whereas the higher crossover frequencies were similar among the samples. The velocity under nDEP was lower for the infected cells than the normal cells. The results imply that the malaria infection significantly decreases the capacitance but increases the conductance of the cell membrane, whereas a change in cytoplasmic conductivity may occur in a later stage of infection.


Assuntos
Eritrócitos , Malária , Humanos , Citoplasma , Membrana Celular , Condutividade Elétrica , Eletroforese/métodos
10.
J Appl Lab Med ; 8(6): 1101-1114, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37725944

RESUMO

BACKGROUND: The serum-free immunoglobulin light chain assay has been recommended as a screening test for monoclonal gammopathy. We evaluated the usefulness of urine free immunoglobulin light concentration for selection of specimens for immunofixation electrophoresis. METHODS: Using kits from The Binding Site for Freelite ®, we validated examination of urine for measuring free κ and λ light chains. The results of urine free light chain concentrations were evaluated to ascertain if the results could be used to reduce the number of specimens requiring urine protein immunofixation electrophoresis. RESULTS: In the 515 specimens examined, there was no evidence of monoclonal gammopathy or history of monoclonal gammopathy in 331. Monoclonal κ or λ light chains were detectable in 42 and 30 specimens, respectively. There was history of κ or λ chain associated monoclonal gammopathy in 62 and 50 patients, respectively. In the 38 monoclonal κ positive urine specimens, with light chain data, κ/λ ratio was >5.83 in all specimens. In 27 specimens positive for monoclonal λ light chains, with light chain data, the urine λ/κ ratio was > 0.17 in 24 of 27 specimens and > 0.041 in all specimens. In patients without monoclonal gammopathy all specimens had a κ/λ ratio of >5.83 or λ/κ ratio >0.17. CONCLUSIONS: The Freelite ® assay from The Binding Site is suitable for quantification of free light chains in urine. In patients with known history of monoclonal gammopathy, urine immunofixation electrophoresis may be omitted in specimens with κ/λ ratio of <5.83 for κ associated lesions and λ/κ ratio of <0.041 for λ associated lesions. However, the results do not support using this test for first-time urine testing for monoclonal light chains as it is not predictive of positive result, nor does it exclude a monoclonal light chain in urine.


Assuntos
Gamopatia Monoclonal de Significância Indeterminada , Paraproteinemias , Humanos , Cadeias Leves de Imunoglobulina/urina , Paraproteinemias/diagnóstico , Cadeias lambda de Imunoglobulina , Eletroforese/métodos
11.
Electrophoresis ; 44(23): 1826-1836, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37622551

RESUMO

Organelle size varies with normal and abnormal cell function. Thus, size-based particle separation techniques are key to assessing the properties of organelle subpopulations differing in size. Recently, insulator-based dielectrophoresis (iDEP) has gained significant interest as a technique to manipulate sub-micrometer-sized particles enabling the assessment of organelle subpopulations. Based on iDEP, we recently reported a ratchet device that successfully demonstrated size-based particle fractionation in combination with continuous flow sample injection. Here, we used a numerical model to optimize the performance with flow rates a factor of three higher than previously and increased the channel volume to improve throughput. We evaluated the amplitude and duration of applied low-frequency DC-biased AC potentials improving separation efficiency. A separation efficiency of nearly 0.99 was achieved with the optimization of key parameters-improved from 0.80 in previous studies (Ortiz et al. Electrophoresis, 2022;43;1283-1296)-demonstrating that fine-tuning the periodical driving forces initiating the ratchet migration under continuous flow conditions can significantly improve the fractionation of organelles of different sizes.


Assuntos
Técnicas Analíticas Microfluídicas , Organelas , Eletroforese/métodos
12.
Electrophoresis ; 44(19-20): 1519-1538, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37548630

RESUMO

The broadening of analyte streams, as they migrate through a free-flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non-idealities in the system, such as Joule heating, pressure-driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte. The injection process can further increase the stream width in FFE separations but normally influencing all analyte zones to an equal extent. Recently, several experimental and theoretical works have been reported that thoroughly investigate the various contributions to stream variance in an FFE device for better understanding, and potentially minimizing their magnitudes. In this review article, we carefully examine the findings from these studies and discuss areas in which more work is needed to advance our comprehension of the zone broadening contributions in FFE assays.


Assuntos
Eletroforese , Eletroforese/métodos , Difusão , Condutividade Elétrica
13.
J Chromatogr A ; 1706: 464240, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37544238

RESUMO

Deterministic Lateral Displacement (DLD) exploits periodic arrays of pillars inside microfluidic channels for high-precision sorting of micro- and nano-particles. Previously we demonstrated how DLD separation can be significantly improved by the addition of AC electrokinetic forces, increasing the tunability of the technique and expanding the range of applications. At high frequencies of the electric field (>1 kHz) the behaviour of such systems is dominated by Dielectrophoresis (DEP), whereas at low frequencies the particle behaviour is much richer and more complex. In this article, we present a detailed numerical analysis of the mechanisms governing particle motion in a DLD micropillar array in the presence of a low-frequency AC electric field. We show how a combination of Electrophoresis (EP) and Concentration-Polarisation Electroosmosis (CPEO) driven wall-particle repulsion account for the observed experimental behaviour of particles, and demonstrate how this complete model can predict conditions that lead to electrically induced deviation of particles much smaller than the critical size of the DLD array.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Tamanho da Partícula , Eletroforese/métodos , Eletricidade , Eletro-Osmose
14.
J Vis Exp ; (196)2023 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-37395572

RESUMO

Human mesenchymal stem cells (hMSCs) offer a patient-derived cell source for conducting mechanistic studies of diseases or for several therapeutic applications. Understanding hMSC properties, such as their electrical behavior at various maturation stages, has become more important in recent years. Dielectrophoresis (DEP) is a method that can manipulate cells in a nonuniform electric field, through which information can be obtained about the electrical properties of the cells, such as the cell membrane capacitance and permittivity. Traditional modes of DEP use metal electrodes, such as three-dimensional electrodes, to characterize the response of cells to DEP. In this paper, we present a microfluidic device built with a photoconductive layer capable of manipulating cells through light projections that act as in situ virtual electrodes with readily conformable geometries. A protocol is presented here that demonstrates this phenomenon, called light-induced DEP (LiDEP), for characterizing hMSCs. We show that LiDEP-induced cell responses, measured as cell velocities, can be optimized by varying parameters such as the input voltage, the wavelength ranges of the light projections, and the intensity of the light source. In the future, we envision that this platform could pave the way for technologies that are label-free and perform real-time characterization of heterogeneous populations of hMSCs or other stem cell lines.


Assuntos
Células-Tronco Mesenquimais , Técnicas Analíticas Microfluídicas , Humanos , Eletroforese/métodos , Linhagem Celular , Eletricidade , Eletrodos , Técnicas Analíticas Microfluídicas/métodos
15.
Electrophoresis ; 44(23): 1756-1773, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37438973

RESUMO

Much progress has been made in the electrokinetic phenomena inside nanochannels in the last decades. As the dimensions of the nanochannels are compatible to that of the electric double layer (EDL), the electrokinetics inside nanochannels indicate many unexpected behaviors, which show great potential in the fields of material science, biology, and chemistry. This review summarizes the recent development of nanofluidic electrokinetics in both fundamental and applied research. First, the techniques for constructing nanochannels are introduced to give a guideline for choosing the optimal fabrication technique based on the specific feature of the nanochannel. Then, the theories and experimental investigations of the EDL, electroosmotic flow, and electrophoresis of nanoparticles inside the nanochannels are discussed. Furthermore, the applications of nanofluidic electrokinetics in iontronics, sensing, and biomolecule separation fields are summarized. In Section 5, some critical challenges and the perspective on the future development of nanofluidic electrokinetics are briefly proposed.


Assuntos
Eletro-Osmose , Eletroforese/métodos
16.
Electrophoresis ; 44(23): 1810-1817, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37439369

RESUMO

Electrophoresis of a dielectric fluid droplet with constant surface charge density is investigated theoretically in this study. A pseudo-spectral method based on Chebyshev polynomials is adopted to solve the governing electrokinetic equations. It is found, among other things, that the larger the electrolyte strength in the ambient solution is, the slower the droplet moves in general. This is due to the strong screening effect of the large amount of indifferent counterions in the neighborhood of the droplet, with no reinforcement of potential-determining ions adsorbing to the droplet surface. The droplet comes to a complete halt eventually. Critical points are discovered for highly charged droplets, at which the droplet surface becomes immobile and the interior fluid stops recirculating. The droplet moves like a rigid particle with constant mobility regardless of its viscosity, a situation referred to as the "solidification phenomenon." The deadlock between the spinning motions on the charged droplet surface induced by the electric driving force and the hydrodynamic driving force respectively is responsible for this peculiar phenomenon. This is also observed for a dielectric droplet with constant surface electric potential. We demonstrate here that it occurs in the constant surface charge density situation as well.


Assuntos
Eletricidade , Eletrólitos , Íons , Eletroforese/métodos , Hidrodinâmica
17.
Electrophoresis ; 44(15-16): 1234-1246, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37431197

RESUMO

Dielectrophoresis (DEP) is a successful method to recover nanoparticles from different types of fluid. The DEP force acting on these particles is created by an electrode microarray that produces a nonuniform electric field. To apply DEP to a highly conducting biological fluid, a protective hydrogel coating over the metal electrodes is required to create a barrier between the electrode and the fluid. This protects the electrodes, reduces the electrolysis of water, and allows the electric field to penetrate into the fluid sample. We observed that the protective hydrogel layer can separate from the electrode and form a closed domed structure and that collection of 100 nm polystyrene beads increased when this occurred. To better understand this collection increase, we used COMSOL Multiphysics software to model the electric field in the presence of the dome filled with different materials ranging from low-conducting gas to high conducting phosphate-buffered saline fluids. The results suggest that as the electrical conductivity of the material inside the dome is reduced, the whole dome acts as an insulator which increases electric field intensity at the electrode edge. This increased intensity widens the high-intensity electric field factor zone resulting in increased collection. This informs how dome formation results in increased particle collection and provides insight into how the electric field can be intensified to the increase collection of particles. These results have important applications for increasing the recovery of biologically-derived nanoparticles from undiluted physiological fluids that have high conductance, including the collection of cancer-derived extracellular vesicles from plasma for liquid biopsy applications.


Assuntos
Eletricidade , Software , Eletroforese/métodos , Condutividade Elétrica , Eletrodos
18.
Anal Methods ; 15(24): 2971-2978, 2023 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-37309647

RESUMO

Cholesterol (CHO) in human blood is one of the most frequently and crucially quantified substances in diagnostic laboratories. However, visual and portable point of care testing (POCT) methods have been rarely developed for the bioassay of CHO in blood samples. Here, we developed an electrophoresis titration (ET) model, a chip device of ∼60 grams, and a quantification method for the POCT of CHO in blood serum based on a moving reaction boundary (MRB). In this model, the selective enzymatic reaction is integrated with an ET chip for visual and portable quantification. At first, CHO reacted with cholesterol oxidase (CHOx) in the anode well, producing H2O2 and cholest-4-en-3-one in the solution. H2O2 further oxidized the colorless and chargeless leucocrystal violet (LCV) dye into violet colored positively charged crystal violet (CV+) and, under the influence of the electric field, the CV+ migrates in the ET channels and is titrated by the alkali of sodium hydroxide immobilized in the ET channels. The length covered by the MRB was measured as a function of the CHO content. The relevant experiments validated the feasibility of the model and method. Furthermore, the experiments revealed the high selectivity, portability, and visuality of the ET-MRB model, device, and method. Finally, the experiments showed a fair sensitivity of LOD of 5 µM, good linearity of 10-1000 µM (r2 = 0.9919), fair stability (intra-day RSD of less than 5.09% and an inter-day RSD of less than 6.36%), and high recovery (99.4-105%). All the data and results indicate the potential of the ET-MRB model, chip device, and method for POCT of CHO in human blood samples.


Assuntos
Peróxido de Hidrogênio , Soro , Humanos , Peróxido de Hidrogênio/química , Eletroforese/métodos , Colesterol Oxidase , Testes Imediatos
19.
J Chromatogr A ; 1702: 464079, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37263054

RESUMO

In recent years, microfluidic-based particle/cell manipulation techniques have catalyzed significant advances in several fields of science. As an efficient, precise, and label-free particle/cell manipulation technique, dielectrophoresis (DEP) has recently attracted widespread attention. This paper presents the design and investigation of a straight sheathless 3D microchannel with a wall-mounted trapezoidal obstacle for continuous-flow separation of three different populations of polystyrene (PS) particles (5, 10 and 20 µm) using DEP. An OpenFOAM code is developed to simulate and investigate the movement of particles in the microchannel. Then, the code is validated by performing various experimental tests using a microdevice previously fabricated in our lab. By comparing the numerical simulation results with the experimental tests, it can be claimed that the newly developed solver is highly accurate, and its results agree well with experimental tests. Next, the effect of various operational and geometrical parameters such as obstacle height, applied voltage, electrode pairs angle, and flow rate on the efficient focusing and separation of particles are numerically investigated. The results showed that efficient particle separation could only be achieved for obstacle heights of more than 350 µm. Furthermore, the appropriate voltage range for efficient particle separation is increased by decreasing the electrode angle as well as increasing the flow rate. Moreover, the results showed that by employing the appropriate channel design and operational conditions, at a maximum applied voltage of 10V, a sample flow rate of 2.5µL/min could be processed. The proposed design can be beneficial for integrating with lab-on-a-chip and clinical diagnosis applications due to advantages, such as simple design, no need for sheath flow, the simultaneous ternary separation of particles, and providing precise particle separation.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Tamanho da Partícula , Desenho de Equipamento , Microfluídica/métodos , Simulação por Computador , Eletrodos , Eletroforese/métodos , Separação Celular
20.
Biomater Adv ; 151: 213476, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37276690

RESUMO

Cancer is a cellular-based disease, so cytological diagnosis is one of the main challenges for its early detection. An extensive number of diagnostic methods have been developed to separate cancerous cells from normal ones, in electrical methods attract progressive attention. Identifying and specifying different cells requires understanding their dielectric and electric properties. This study evaluated MDA-MB-231, HUVEC, and MCF-10A cell lines, WBCs isolated from blood, and patient-derived cell samples with a cylindrical body with two transparent FTO (fluorine-doped tin oxide) plate electrodes. Cell mobility rates were recorded in response to these stimuli. It was observed that cancer cells demonstrate drastic changes in their motility in the presence and absence of an electric field (DC/AC). Also, solution viscosity's effect on cancer cells' capturing efficacy was evaluated. This research's main distinguished specification uses a non-microfluidic platform to detect and pathologically evaluate cytological samples with a simple, cheap, and repeatable platform. The capturing procedure was carried out on a cytological slide without any complicated electrode patterning with the ability of cytological staining. Moreover, this platform successfully designed and experimented with the invasion assay (the ability of captured cancer cells to invade normal cells).


Assuntos
Eletroforese , Neoplasias , Eletroforese/instrumentação , Eletroforese/métodos , Neoplasias/diagnóstico , Neoplasias/patologia , Invasividade Neoplásica , Eletrodos , Humanos , Linhagem Celular Tumoral , Impressão Tridimensional , Separação Celular , Hipóxia Celular , Ensaios de Migração Celular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...